A dimly lit historic parlor with a chandelier, wooden furniture, and two windows

Prefab Fireplace and Chase Repair in Sherman Oaks

Book a Fireplace Visit

Name, number and the job. We get back to you to arrange a time.

Listed parts by modelWritten scope first
Data Plate Read First
Listed Parts by Model
Written Scope Before Work
Based in Sherman Oaks
Data Plate Read First
Listed Parts by Model
Written Scope Before Work
Based in Sherman Oaks
Graves Services From Sherman Oaks

Prefab fireboxes first, then everything above them

Refractory panels, dampers and screens inside; pipe, chase top and listed cap outside. Brick stacks, gas units and stoves are on the list as well, each priced on paper before work.

Chimney Sweep

Brushing and vacuuming for listed metal chimney pipe and clay flues, with the cap lifted and the firebox left clean.

Open this service

Chimney Inspection

NFPA 211 Level 1, 2 or 3 inspections for prefab metal systems and brick chimneys, each written up with photos.

Open this service

Chimney Repair

Repairs to metal chimney pipe, chase framing and siding, and to brick stacks: tops, joints, spacers and caps.

Open this service

Fireplace Inspection

A room-side check of the firebox, panels, screen, doors and hearth, read against the maker's listing for prefab units.

Open this service

Fireplace Repair

Panel, damper, screen, door and grate repairs on prefab fireplaces, using parts listed for the model on the data plate.

Open this service

Chimney Level 2 Inspection

Recorded video of the whole chimney pipe plus the chase and attic framing, for sales, fires, quakes and changed appliances.

Open this service

Chimney Cap Installation

Caps listed for your metal chimney pipe or sized to a clay flue, measured on the roof and fastened against wind.

Open this service

Chimney Flashing Repair

Leaks at the roof line around a brick or framed chimney traced to the metal and resealed, with a cricket where needed.

Open this service

Chimney Masonry Repair

Brick stacks with sandy joints, chipped faces or white staining repointed and patched with brick and mortar that match.

Open this service

Chimney Rebuilds

Brick stacks cracked through or loose at the top taken down and rebuilt, or replaced with a framed chase and listed pipe.

Open this service

Fireplace Cleaning

Ash, soot and fallen debris cleared from the firebox, with prefab panels brushed gently so they are not scored.

Open this service

Gas Fireplace Cleaning

Burner, pilot, media and glass cleaned on sealed gas units, followed by a flame check and a carbon monoxide reading.

Open this service

Gas Fireplace Repair

Pilots that drop out, burners that stay dark and remotes that stopped answering, tested part by part before anything is ordered.

Open this service

Fireplace Remodel

New faces, hearths and mantels around prefab or brick fireboxes, built inside the clearances the unit's manual allows.

Open this service

Fireplace Inserts

Gas and wood inserts for brick fireplaces, plus a check of whether your prefab box is listed to accept one at all.

Open this service

Pellet Stove Repair

Pellet stoves that quit mid-burn or flash a fault code: motors, igniters, switches and boards tested before parts are ordered.

Open this service

Wood Stove Repair

Freestanding stoves with leaking door seals, sagging baffles, cracked brick or tired catalysts put back in order.

Open this service

Gas Logs

Vented log sets for brick fireboxes and for prefab units listed to take them, piped, valved and lit before we leave.

Open this service

Chimney Seismic Retrofit

Brick chimneys on wood-frame houses braced, strapped or cut down and topped with lighter framing, with options set out on paper.

Open this service

Chimney Crown Repair

Cracked or crumbling mortar tops on brick stacks sealed, or poured new with an overhang that sheds water.

Open this service

Dryer Vent Cleaning

Lint packed in the duct from dryer to outside wall or roof cleared, and the outside flap freed so it opens.

Open this service

Chimney Liner Installation

Stainless liners for brick flues with cracked tile or a new appliance, and listed pipe replacements for prefab chimneys.

Open this service

Chimney Leak Repair

Water at the ceiling, wall or firebox traced to the chase top, cap, flashing, siding or brick, then repaired at that point.

Open this service

Chimney Waterproofing

A breathable water repellent on brick and block chimneys, applied after joints, top and flashing are made sound.

Open this service

Chimney Damper Repair

Prefab damper blades, springs and handles refitted to the listing; brick fireplace dampers freed, replaced or moved to the top.

Open this service

Chimney Chase Cover

Rusted or dished metal tops on framed chases replaced with a custom-cut stainless top that sheds water off the edges.

Open this service
Graves, Sherman Oaks

Metal fireplaces, repaired to their listing.

Graves Chimney Experts works out of Sherman Oaks, where a large share of the houses built from the 1970s on have a metal fireplace set into a wood-framed wall, with round pipe running up through a framed chase.

Those units were tested by their makers as complete sets. A panel, damper or cap from another brand puts the set outside that test, so we order by the model on the data plate and fit parts the way the manual shows.

Outside, the weak points are the metal top of the chase, the seams in its siding and the flashing at the roof. Brick stacks and sealed gas units get the same written scope and price before any work starts.

Model number recorded before parts are named
Scope and price on paper before work
Photos from the firebox, the chase and the roof
Repairs kept inside the maker's listing
Cottage with brick chimneys behind autumn leaves
Data Plate
Read before parts are ordered

Listing Before Labor

A prefab fireplace is safe at the clearances its maker tested. Every job starts from the data plate, and the repair stays inside that listing.

Parts by Model Number

Panels, dampers, caps and chase tops are ordered for the unit in your wall. Where a model is out of production, you hear it before anyone spends money.

Scope in Writing

Each repair is described and priced on paper first. If opening something shows more, you see it and decide.

Built Around Tract Homes

Much of the housing around Sherman Oaks went up with framed chases and metal fireplaces. That is the work this company is organized around.

How Graves Runs a Job

Unit, Listing, Inspection, Scope, Test

Five steps on every fireplace in Sherman Oaks and the cities around it. The model on the data plate sets the parts before anything is ordered.

1

Tell Us the Unit

Use the contact form. Note whether the fireplace is a metal box or brick, and what has changed: a crack, rust, a pilot, water. A model number from the data plate, if you can find it, lets us bring the right parts.

2

Read the Listing

At the house we find the data plate and pull the maker's manual for that model. Clearances, approved parts and the cap that belongs on the pipe all come from it.

3

Inspect Room to Roof

We work from the firebox up through the chase to the top, noting each finding with a photo and where it sits.

4

Price It on Paper

You get a written scope: the parts, by model where they apply, the labor and the price. Nothing starts until you agree to it.

5

Fit and Test

Listed parts go in as the manual shows. Then we test what we touched: a draft check, a full gas cycle with a CO reading, or a hose run over new metal.

Step one is the request form.

Request a Visit

Prefab Fireplace Needs Parts in Sherman Oaks?

Cracked refractory panels, a damper handle that will not move, a chase top bleeding rust down the siding. Graves reads the data plate, orders the listed part for that model and writes the scope and price before fitting it.

Request form
Request a Visit
Written scope first
Sherman Oaks and nearby cities

Book a Fireplace Visit

Name, number and the job you need. We get back to you to arrange a time.

By sending, you agree Graves Chimney Experts may contact you by call, automated text or email about your request. Consent isn't required to buy. Msg & data rates may apply; reply STOP to opt out. Privacy Policy

Listed Parts
Model on File
Graves Coverage

Sherman Oaks, Burbank, Calabasas, Santa Clarita and beyond

Type a city to read which fireplaces we meet there and what tends to wear on them.

Based in Sherman Oaks

Metal box in a framed chase?

That is most of our work. Panels, dampers, chase tops and listed caps are ordered by the model on the data plate, and the scope is written before anything is fitted.

Graves Answers

Prefab Fireplace Questions, Answered Plainly

Listings, panels, chase tops, gas pilots and sale inspections: the topics owners in Sherman Oaks and nearby cities raise before booking.

Question not covered?

Put it on the request form along with the fireplace model, if you have it.

Request a Visit
Open the screen and look at the firebox walls. Smooth panels in a steel frame, a round metal pipe above the box and a data plate on the side or under the floor all point to a prefab unit. Brick or block with mortar joints is masonry. Outside, a box clad in stucco or siding with a metal top is a framed chase. If it is still unclear, the inspection settles it.
The unit was tested as a set: box, panels, damper, pipe and cap. That test is what lets it sit close to wood framing. Mixing in parts from another brand, or a generic cap, leaves a combination nobody tested, and an inspector on a sale will write it up. We order by the model on the data plate and tell you plainly when a model has gone out of production.
A thin line across a panel is common, and most manuals give a width limit. A gap a coin fits into, a piece that has fallen out, or bare steel showing behind the panel means the box is losing its insulation, and fires should stop until the panel set is replaced. We measure it against the maker's limit and tell you which side it falls on.
It is the roof of the framed box the chimney pipe runs through. Older galvanized tops were flat, so rain sat in the middle and rusted them through, and the water then reached the studs and the firebox below. Rust streaks down the siding or water in the firebox are the usual signs. A stainless replacement is bent to your chase size, with cross-breaks to shed water.
Not at first. Walk everyone out, leave lights and switches as they are, and phone for help from the sidewalk. After the supply has been shut and cleared, book us to trace the leaking fitting or valve in the fireplace and replace it.
Yes. A garage joined to the house, any fireplace, or an appliance that burns fuel each puts a home under the state rule for CO alarms. A sealed gas unit that is working right sends its exhaust outdoors, but a torn gasket or a blocked vent can change that, which is why we take a CO reading in the room on every gas visit.
Yes, for wood. From November through February the South Coast air district can declare a no-burn day when smoke would hang over the basin, under its Rule 445. Gas fireplaces are exempt. If those days are what keep you from using the fireplace, a gas insert or a log set is the usual answer.
Usually not. A pilot that dies when the knob is released points to the sensor the flame heats, either worn out or sitting in a weak, dirty flame. If the pilot holds and the main burner stays dark, the cause is more often the thermopile, the switch or the remote receiver. We read each with a meter and replace just that piece.
Buyers' agents usually ask for a Level 2, and the NFPA 211 standard backs them on it for a sale. On a prefab system it matters more than on brick, because the pipe and its joints sit inside the chase where a flashlight cannot reach. Ours is $410, and the report goes to whoever you name.
Only for a Level 3, and only when a Level 2 shows trouble the camera cannot settle, such as scorched framing near the chase or pipe that has shifted behind a finished wall. We explain why before anything is cut and price it on its own.
One visit, two systems. Each prefab unit has its own pipe and cap, and each gets its own inspection and its own price, so two units means two line items on the invoice.
No. Two stacks that look alike from the yard can hide very different joints and tops, so we look first and then write the scope and the figure. Crickets, leak repair and both inspection levels have published prices. Caps are quoted after we measure, and brick work after we look.
Call (747) 224-9117